NEW SHXF Circulating Fluidized Bed CFB Boiler
Total 15658


SHXF Circulating Fluidized Bed CFB Boiler for sale

ID: 2322   
Units Available:   1
Category: Coal Fired Boilers
International Certifications: EU, China, USA
NEW
Mileage Hrs/Kms: 0
Year of Manufacture: 2024
The price: P.O.A.
Why wait? There's no better time to reserve than right NOW

NEW industrial SHXF Circulating Fluidized Bed CFB Boiler for Power Plant, central heating, chemical industry etc.

Certificates: ISO9001, ISO45001, ISO14001, CE, EAC
Fuel: Lignite,Bituminous Coal,Lean Coal, Anthracite

SHXF series CFB boiler is a large capacity boiler, the new type boiler makes big breakthrough on the technology of cyclone fluid combustion, cyclone separation structure & parametric design, and loop seal device. It is consist of combustion chamber, separator, fly ash circulating system, superheater, convection bank, economizer, and air preheater. The boiler inherits the original technology advantages, at the same time, makes big breakthrough on the technology of cyclone fluid combustion, cyclone separation structure & parametric design, and loop seal device. The thermal efficiency is about 5% higher than the other CFB boilers.

Technical Advantages of the Circulating Fluidized Bed CFB Boiler
1. Available to Burn Low Grade Fuel
Longer Fuel Combustion Period. Front arch is higher and shorter than rear arch, 45° angle between the two arches,
which can extend the time of flue gas combustion time, and enhance thermal transferring efficiency.
It also can burn low calorific value coal such as brown coal, lean coal, and semi coke.
2. Durable And Stable Grates
It adopts Global Environmental Facility special slag removal technology, and small flake gate, to overcome
technical problem such as grate flakes falling off and air leakage, so that the grate can be operated stably
and the combustion efficiency is greatly improved.
The boiler grate adopts double layers or single layer layout structure, which can meet the customers requirements better.
3. Double Cyclone Separator
After separated by the second cyclone, the fuel powder particles return to furnace for circulating combustion
through the separate loop seal. The diameter of particles could be cut into 10? by separator, improve the combustion efficiency.
4. Parametrization Design on Separator
Using the results of latest experiment, redesign the parameter of separator, optimize the line and size of cyclone separator,
the separate efficiency improved greatly.
5. Bubbling Fluid Loop Seal Technology
Using the hood bubbling fluid integrate loop seal device, achieve the situation of bubbling fluid.
It has the advantages of material feed steadily, convenient control, and avoid coking.
6. Cyclone Combustion Technology
Arrange cyclone combustion device in furnace, achieves cyclone fluidized circulating combustion, improve combustion efficiency.
7. Membrane water wall
The furnace, separator and loop seal device adopts membrane water wall, prevents the low efficiency caused by air leakage, low heat loss.
8. Anti wear design
The buried pipe adopts anti-wear steel with the special size and angle, and reduce the fluidization velocity, to reduce the wear.
The high temperature resistant material is deposited on the water cooling wall of the separator, avoiding the abrasion of membrane wall.

Boiler System

Auxiliary


In-sale service:
We keep 24 hours online and keep close contacts during the production process to ensure on time delivery with perfect finished product.
After-sale service:
1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is available.
3. Our engineers will held a training for boiler workers to ensure the safe operation.
4. Free maintenance and repair for one year and lifelong service.

The specification of the SHXF Circulating Fluidized Bed CFB Boiler

Model SHXF15-1.25-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 15
-------------------------------------------
Rated Evaporation BHP 1149
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 194
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF15-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 15
-------------------------------------------
Rated Evaporation BHP 1149
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃) 204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF15-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 15
-------------------------------------------
Rated Evaporation BHP 1149
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF20-1.25/350-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 350
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF20-1.25-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 194
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF20-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃) 204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF20-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF35-1.25-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 35
-------------------------------------------
Rated Evaporation BHP 2681
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 194
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF35-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 35
-------------------------------------------
Rated Evaporation BHP 2681
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃) 204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF35-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 35
-------------------------------------------
Rated Evaporation BHP 2681
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h SHXF75-1.25-H
-------------------------------------------
Rated Evaporation BHP 75
-------------------------------------------
Rated Steam Pressure (bar) 5745
-------------------------------------------
Rated Steam Temperature (℃) 12.5
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF75-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 75
-------------------------------------------
Rated Evaporation BHP 5745
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃)204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Model SHXF75-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 75
-------------------------------------------
Rated Evaporation BHP 5745
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------

Note: 1. Parameter is for reference only, if any changes should follow the factory technical data.
2. Our company can design boiler products based on customers requirement and different biomass fuels.


Warranty terms service
12 months since arrival at destination port
SHXF Circulating Fluidized Bed CFB Boiler  for sale SHXF Circulating Fluidized Bed CFB Boiler  for sale SHXF Circulating Fluidized Bed CFB Boiler for sale SHXF Circulating Fluidized Bed CFB Boiler | NEW military vehicles, MOD surplus for sale SHXF Circulating Fluidized Bed CFB Boiler | NEW military vehicles, MOD surplus for sale


Customize product service
We can put the label of your logo on the products or make the silk print of your logo on the products. It is free.
OEM and ODM are welcomed from GT. We have rich experiences in this area.

Pre-sale service service
Arranging of independent inspection
We can provide a full Pre-sale service
Please see more

SPARE PARTS +
We have a full stock of spare parts. These parts are always on stock which avoids and delays in ordering.

SHIPPING SHIPPING
We can arrange shipping from our yard to your door worldwide.
Well choose the nearest shipping place to ship at the shortest time. Please see more

NEW-MACHINERY®


army-uk.com ©
Materials and specifications are subject to change without notice.
Featured machines in photos may include additional equipment. The specification do not necessarily show the standard version of the machine.
Ask our manager for available options.
09.00 - 17.00 hrs Monday - Friday
Not available on Saturday's or Sunday's

Article printed at 2024-03-28. Please see https://army-uk.com/equip.php?ID=2322 for the latest version.