Description SHXF Circulating Fluidized Bed CFB Boiler
Factory Direct
Fast shipping
Full warranty and all spare parts
Are you still wasting time looking for Coal Fired Boilers suppliers?
Do you still worry about product quality assurance?
Are you late in deciding to buy because of insufficient budget?
If you have these worries, stay and see.
NEW industrial SHXF Circulating Fluidized Bed CFB Boiler for Power Plant, central heating, chemical industry etc.
Certificates: ISO9001, ISO45001, ISO14001, CE, EAC
Fuel: Lignite,Bituminous Coal,Lean Coal, Anthracite
SHXF series CFB boiler is a large capacity boiler, the new type boiler makes big breakthrough on the technology of cyclone fluid combustion, cyclone separation structure & parametric design, and loop seal device. It is consist of combustion chamber, separator, fly ash circulating system, superheater, convection bank, economizer, and air preheater. The boiler inherits the original technology advantages, at the same time, makes big breakthrough on the technology of cyclone fluid combustion, cyclone separation structure & parametric design, and loop seal device. The thermal efficiency is about 5% higher than the other CFB boilers.
Technical Advantages of the Circulating Fluidized Bed CFB Boiler 1. Available to Burn Low Grade FuelLonger Fuel Combustion Period. Front arch is higher and shorter than rear arch, 45° angle between the two arches,
which can extend the time of flue gas combustion time, and enhance thermal transferring efficiency.
It also can burn low calorific value coal such as brown coal, lean coal, and semi coke.
2. Durable And Stable GratesIt adopts Global Environmental Facility special slag removal technology, and small flake gate, to overcome
technical problem such as grate flakes falling off and air leakage, so that the grate can be operated stably
and the combustion efficiency is greatly improved.
The boiler grate adopts double layers or single layer layout structure, which can meet the customers requirements better.
3. Double Cyclone SeparatorAfter separated by the second cyclone, the fuel powder particles return to furnace for circulating combustion
through the separate loop seal. The diameter of particles could be cut into 10? by separator, improve the combustion efficiency.
4. Parametrization Design on SeparatorUsing the results of latest experiment, redesign the parameter of separator, optimize the line and size of cyclone separator,
the separate efficiency improved greatly.
5. Bubbling Fluid Loop Seal TechnologyUsing the hood bubbling fluid integrate loop seal device, achieve the situation of bubbling fluid.
It has the advantages of material feed steadily, convenient control, and avoid coking.
6. Cyclone Combustion TechnologyArrange cyclone combustion device in furnace, achieves cyclone fluidized circulating combustion, improve combustion efficiency.
7. Membrane water wallThe furnace, separator and loop seal device adopts membrane water wall, prevents the low efficiency caused by air leakage, low heat loss.
8. Anti wear designThe buried pipe adopts anti-wear steel with the special size and angle, and reduce the fluidization velocity, to reduce the wear.
The high temperature resistant material is deposited on the water cooling wall of the separator, avoiding the abrasion of membrane wall.
Boiler SystemAuxiliary In-sale service:We keep 24 hours online and keep close contacts during the production process to ensure on time delivery with perfect finished product.
After-sale service:1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is available.
3. Our engineers will held a training for boiler workers to ensure the safe operation.
4. Free maintenance and repair for one year and lifelong service.
The specification of the SHXF Circulating Fluidized Bed CFB Boiler
Model SHXF15-1.25-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 15
-------------------------------------------
Rated Evaporation BHP 1149
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 194
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF15-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 15
-------------------------------------------
Rated Evaporation BHP 1149
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃) 204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF15-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 15
-------------------------------------------
Rated Evaporation BHP 1149
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF20-1.25/350-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 350
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF20-1.25-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 194
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF20-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃) 204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF20-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 20
-------------------------------------------
Rated Evaporation BHP 1532
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF35-1.25-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 35
-------------------------------------------
Rated Evaporation BHP 2681
-------------------------------------------
Rated Steam Pressure (bar) 12.5
-------------------------------------------
Rated Steam Temperature (℃) 194
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF35-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 35
-------------------------------------------
Rated Evaporation BHP 2681
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃) 204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF35-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 35
-------------------------------------------
Rated Evaporation BHP 2681
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h SHXF75-1.25-H
-------------------------------------------
Rated Evaporation BHP 75
-------------------------------------------
Rated Steam Pressure (bar) 5745
-------------------------------------------
Rated Steam Temperature (℃) 12.5
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF75-1.6-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 75
-------------------------------------------
Rated Evaporation BHP 5745
-------------------------------------------
Rated Steam Pressure (bar) 16
-------------------------------------------
Rated Steam Temperature (℃)204
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Model SHXF75-2.5-H Circulating Fluidized Bed CFB Boiler
-------------------------------------------
Rated Evaporation t/h 75
-------------------------------------------
Rated Evaporation BHP 5745
-------------------------------------------
Rated Steam Pressure (bar) 25
-------------------------------------------
Rated Steam Temperature (℃) 226
-------------------------------------------
Water Temperature (℃) 105
-------------------------------------------
Fuel Lignite,Bituminous Coal,Lean Coal, Anthracite
-------------------------------------------
Factory Mode Field Assembly
-------------------------------------------
Note: 1. Parameter is for reference only, if any changes should follow the factory technical data.
2. Our company can design boiler products based on customers requirement and different biomass fuels.